Shanghai Qiyi International Trade Co., Ltd.
Main products:prepaid water meter,Gprs water meter,RF remote water meter,flow meter,GSM remote water meter
Products
Contact Us
  • Contact Person : Ms. Li Adine
  • Company Name : Shanghai Qiyi International Trade Co., Ltd.
  • Tel : 86-21-31267690
  • Fax : 86-21-61264329
  • Address : Shanghai,Shanghai,Room1615 No.3 Building, No.1088 Jiefangdong Road,Fengxian
  • Country/Region : China
  • Zip : 201400

INTELLIGENT TURBINE FLOWMETER

INTELLIGENT TURBINE FLOWMETER
Product Detailed
16 bits microprocessor -MSP430 7 points linear correction of K-factor Flowrate/Total flow quantity display 1.     FEATURES

     Intelligent turbine flowmeter & Intelligent turbine flow transducer adopts MSP430 from TI Co. USA for microprocessor. Using hard alloy bearing in turbine sensor, the flowmeter can be widely applied in measurement of water, gasoline or various low viscosity fluids. Intelligent turbine flowmeter displays flowrate and total quantity on the LCD simultaneously. 4-20mA standard current signals are output by the intelligent turbine flow transducer, which can be connected to PLC or DCS computer and so on. The intelligent turbine flowmeter provides the function of correction of non-linear instrument coefficient in order to achieve higher accuracy, if necessary.

2.     TECHNICAL PARAMETERS

a)      Temperature of fluid  -20°C~+120°C

b)      Temperature of environment  0°C~+50°C

c)      Accuracy ±0.5%  1%

d)      Li-MnO2 battery (inside) can work for over 6 years

e)      Transducer output 4-20mA signals  resistance<500Ω

f)       LCD displays flowrate(6 digits) & total quantity(8 digits)

g)      Power-off protection of total quantity and K-factor, protect time more than 10 years

TYPE

DN

(mm) 

RANGE OF FLOW

(m3/h)

PRESSURE

(MPa)

FIXING

ACCURACY    

(%)

KY-LWGY-4

4

0.04-0.25

6.3

 G1/2  

0.5  1.0

KY-LWGY-6

6

0.1-0.6

6.3

 G1/2

0.5  1.0

KY-LWGY-10

10

0.2-1.2

6.3

 G1/2

0.5  1.0

KY-LWGY-15

15

0.6-6

6.3

 G1

0.5

KY-LWGY-20

20

0.8-8

6.3

 G5/4

0.5

KY-LWGY-25

25

1-10

6.3

 G5/4

0.5

KY-LWGY-32

32

1.6-16

6.3

 G5/4

0.5

KY-LWGY-40

40

2-20

6.3

 G2

0.5

KY-LWGY-50

50

4-40

2.5

FLANGE

0.5

KY-LWGY-65

65

8-80

2.5

FLANGE

0.5

KY-LWGY-80

80

10-100

2.5

FLANGE

0.5

KY-LWGY-100

100

20-200

2.5

FLANGE

0.5

KY-LWGY-125

125

25-250

2.5

FLANGE

0.5

KY-LWGY-150

150

30-300

2.5

FLANGE

0.5

KY-LWGY-200

200

80-800

2.5

FLANGE

0.5

3.     FIXING  OF  INSTRUMENT

a)      Fixing differs on various sizes of pipes

b)      The instrument can be fixed horizontally, vertically or leaning, the pipe must be full of liquid and without gas in it

c)      Follow the direction indicator on the surface of sensor, upstream length must be more than 20DN, downstream length at least 7DN

d)      Instrument should be away from any electromagnetic field, shielding measures take should be taken if necessary.

e)      If the flowmeter works in open air, a waterproof shell is recommended

INTELLIGENT TURBINE FLOWMETER



Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.